Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
CoDAS ; 34(1): e20200318, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1345823

ABSTRACT

ABSTRACT Purpose To evaluate the agreement among instruments of the quantitative evaluation of hard palate. Methods This cross-sectional study was performed with a sample of 30 children aged 6 to 11 from Santa Maria, Southern Brazil. The instruments for palate measurements evaluated were: digital caliper, used directly in the oral cavity and in plaster casts, Korkhaus tridimensional bow, used directly in the oral cavity and in plaster casts, and Dolphin Imaging Software used for measurements in cone-beam computed tomography (CBCT). The agreement among different instruments was evaluated using the Intraclass Correlation Coefficient (ICC). Results The means of all transversal dimensions obtained by cone-beam computed tomography were lower than those of the other instruments - the agreement values in the width between the canines and in the width between the first molars were lower when comparing the cone-beam computed tomography and the other instruments. In the width between the first and second premolars, all comparisons showed acceptable agreement values. Good concordance values were obtained when comparing the palate depth at the second premolar region when using a bow divider inside the oral cavity and in the cast. Conclusion Most instruments presented satisfactory agreement in the measurements related to the transverse plane of the hard palate. However, when the vertical plane was evaluated, only the bow divider applied to both cast and oral cavity presented ideal agreement.


RESUMO Objetivo Avaliar a concordância entre instrumentos de avaliação quantitativa do palato duro. Método Este estudo transversal foi realizado com uma amostra de 30 crianças de 6 a 11 anos de Santa Maria, sul do Brasil. Os instrumentos de medidas do palato avaliados foram: paquímetro digital, utilizado diretamente na cavidade oral e em modelos de gesso, arco tridimensional Korkhaus, usado diretamente na cavidade oral e em modelos de gesso, e Dolphin Imaging Software utilizado para medições em tomografia computadorizada de feixe cônico (CBCT). A concordância entre os diferentes instrumentos foi avaliada por meio do Coeficiente de Correlação Intraclasse (ICC). Resultados As médias de todas as dimensões transversais obtidas pela tomografia computadorizada de feixe cônico foram menores do que as dos outros instrumentos - os valores de concordância na largura entre os caninos e na largura entre os primeiros molares foram baixos na comparação entre a tomografia computadorizada de feixe cônico e os demais instrumentos. Na largura entre o primeiro e o segundo pré-molar, todas as comparações apresentaram valores de concordância aceitáveis. Valores de concordância aceitáveis também foram obtidos ao comparar a profundidade do palato na região do segundo pré-molar com o uso de um divisor de arco dentro da cavidade oral e no gesso. Conclusão A maioria dos instrumentos apresentou concordância satisfatória nas medidas relacionadas ao plano transverso do palato duro. Porém, quando avaliado o plano vertical, apenas o divisor de arco aplicado tanto no gesso quanto na cavidade oral apresentou concordância ideal.

2.
Dental press j. orthod. (Impr.) ; 26(2): e211955, 2021. tab
Article in English | LILACS, BBO | ID: biblio-1249701

ABSTRACT

ABSTRACT Objective: To assess the color of different orthodontic resin bonding agents exposed to three antiseptic mouthrinses for a prolonged time interval (10-year aging simulation). Methods: 160 specimens were distributed into four groups, according to the orthodontic resin bond agent (Concise, Transbond XT, Transbond Plus Color Change, and Natural Ortho). Each group was exposed to different antiseptic mouthrinses: alcohol-based (Listerine®), alcohol-free (Oral-B®), chlorhexidine (Periogard®) and distilled water as the control. Specimens were submitted to two cycles of staining and artificial aging. Color was evaluated by means of a digital spectrophotometer at the beginning of the experiment and after every cycle. The system used to assess color changes was the CIE L*a*b*. Data was analyzed using the ANOVA and Tukey post-hoc test. Results: After simulation of 10 years of aging, Transbond XT and Natural Ortho composites presented no statistically significant differences in ∆E when exposed to different mouthrinses. The Concise composite specimens exposed to alcohol-free mouthrinse presented a significant difference when compared with specimens from the same group exposed to other antiseptic mouthrinses. Transbond Plus Color Change specimens exposed to chlorhexidine mouthrinse and to alcohol-containing mouthrinse presented a significant difference when compared with the specimens from the group exposed to water and alcohol-free antiseptic. Conclusion: All orthodontic resin bonding agents tested presented clinically perceptible color changes when exposed to at least one of the mouthrinses, except for the Natural Ortho composite. The Concise composite exposed to the alcohol-free solution was the resin that presented the highest color change values.


RESUMO Objetivo: Avaliar a cor de diferentes resinas ortodônticas expostas a três enxaguantes bucais, por um intervalo de tempo prolongado (simulação de 10 anos de envelhecimento). Métodos: 160 espécimes foram distribuídos em quatro grupos, de acordo com a resina de colagem ortodôntica (Concise, Transbond XT, Transbond Plus Color Change e Natural Ortho). Cada grupo foi exposto a diferentes tipos de enxaguantes bucais: à base de álcool (Listerine®), isento de álcool (Oral-B®), clorexidina (Periogard®) ou água destilada, como controle. Os espécimes foram submetidos a dois ciclos de manchamento e envelhecimento artificial. A cor foi avaliada por meio de um espectrofotômetro digital no início do experimento e após cada ciclo. O sistema utilizado para avaliar as alterações de cor foi o CIE L*a*b*. Os dados foram analisados utilizando-se o teste ANOVA e o teste post-hoc de Tukey. Resultados: Após a simulação de 10 anos de envelhecimento, as resinas Transbond XT e Natural Ortho não apresentaram diferenças estatisticamente significativas no ∆E, quando expostas a diferentes enxaguantes bucais. Os espécimes do grupo Concise expostos ao enxaguante bucal sem álcool apresentaram diferença significativa quando comparados aos espécimes do mesmo grupo expostos aos outros enxaguantes bucais. Os espécimes do grupo Transbond Plus Color Change expostos à clorexidina e ao enxaguante bucal à base de álcool apresentaram diferença significativa quando comparados aos espécimes dos grupos expostos à água e ao enxaguante bucal sem álcool. Conclusão: Todas as resinas ortodônticas avaliadas apresentaram alterações de cor clinicamente perceptíveis quando expostas a pelo menos um dos enxaguantes bucais, com exceção da resina ortodôntica Natural Ortho. A resina Concise exposta à solução isenta de álcool foi a que apresentou os maiores valores de alteração de cor.


Subject(s)
Chlorhexidine , Orthodontic Brackets , Composite Resins , Anti-Infective Agents, Local , Materials Testing , Resin Cements , Mouthwashes
3.
Dental press j. orthod. (Impr.) ; 26(1): e211967, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1154066

ABSTRACT

ABSTRACT Objective: Assess the influence of mono- and bicortical anchorage and diameter of mini-implants (MIs) on the primary stability of these devices. Methods: 60 self-drilling MIs were distributed in six groups according to diameter (1.5mm, 1.8mm or 2.0mm) and type of anchorage (monocortical and bicortical) in bovine rib. The primary stability was evaluated by insertion torque, micromobility and pull-out strength tests. ANOVA and/or Tukey analysis were used to conduct intergroup comparisons (p< 0.05). Non-parametric statistics (Kruskal-Wallis and Mann-Whitney) were performed when normality was not found (p< 0.05). Results: MIs with larger diameters and bicortical anchorage showed greater primary stability regarding insertion torque (p< 0.05) and micromobility (p< 0.05). Only MI diameter had an effect on the pull-out strength test. Larger diameter MIs presented better retention in pull-out strength tests (p< 0.001), regardless of mono- or bicortical anchorage. Conclusions: MI primary stability is dependent on its diameter and type of anchorage. Bicortical anchorage showed greater stability when compared with monocortical anchorage, independently of other variables.


RESUMO Objetivo: Avaliar a influência da ancoragem mono e bicortical e do diâmetro dos mini-implantes (MIs) na estabilidade primária desses dispositivos. Métodos: 60 MIs autoperfurantes foram distribuídos em seis grupos, de acordo com o diâmetro (1,5 mm, 1,8 mm ou 2,0 mm) e tipo de ancoragem (monocortical e bicortical), e inseridos em costela bovina. A estabilidade primária foi avaliada pelos testes de torque de inserção, micromobilidade e resistência à tração. ANOVA e/ou análise de Tukey foram usadas para realizar comparações intergrupos (p< 0,05). Estatística não paramétrica (Kruskal-Wallis e Mann-Whitney) foi realizada quando a normalidade não foi encontrada (p< 0,05). Resultados: MIs com diâmetros maiores e ancorados bicorticalmente apresentaram maior estabilidade primária em relação ao torque de inserção (p< 0,05) e micromobilidade (p< 0,05). Apenas o diâmetro do MI influenciou os resultados do teste de resistência à tração. MIs de maior diâmetro apresentaram melhor retenção nos testes de resistência à tração (p< 0,001), independentemente da ancoragem mono ou bicortical. Conclusões: a estabilidade primária do MI é dependente de seu diâmetro e tipo de ancoragem. A ancoragem bicortical apresentou maior estabilidade quando comparada à ancoragem monocortical, independentemente das demais variáveis.


Subject(s)
Humans , Cattle , Dental Implants , Orthodontic Anchorage Procedures , Palate , Palatal Expansion Technique , Torque
SELECTION OF CITATIONS
SEARCH DETAIL